Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.497
Filtrar
1.
Cureus ; 16(3): e56935, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38665726

RESUMO

AIM: In-vitro evaluation of shear bond strength, mode of failure, and adaptation of fifth-generation (etch-and-rinse), seventh-generation,and eighth-generation self-etch dental adhesives to human dentin with or without diode-laser irradiation before photopolymerization. MATERIALS AND METHODS: Seventy-two extracted human maxillary premolar teeth were collected. The buccal and lingual surfaces of teeth were grounded until dentin was exposed. Test areas of 4 mm diameter were created on both surfaces of teeth to standardize the area of treatment. The samples were then randomly allocated into three groups (n = 24): Group 1 Adper Single Bond 2 Etch-and-Rinse; Group 2 Tetric-N-Bond Universal Self-Etch; Group 3 Prime and Bond Universal Self-Etch dental adhesives were used. Buccal surfaces (sub-groups 'a') of all specimens were irradiated with diode laser before photopolymerization of the adhesive material, and palatal surfaces (sub-groups 'b') were directly photopolymerized without prior diode laser irradiation and restored with composite resin. All specimens were thermocycled. Four specimens from each group were then subjected to scanning electron microscopy (SEM) analysis to examine the adaptation of adhesive to dentin, and the remaining 60 specimens were evaluated for shear bond strength tests, modes of failure at the adhesive-dentin interface, and values were recorded, tabulated, and used for data analysis. A one-way ANOVA test and the Student's t-test were used for statistical analysis. A P value ≤ 0.05 was considered statistically significant. RESULTS: The mean shear bond strength for the groups was: Group 1a (13.96 MPa), 1b (14.95 MPa); Group 2a (10.06 MPa), 2b (10.30 MPa); Group 3a (12.03 MPa), and 3b (10.44 MPa). No statistically significant difference was seen among sub-groups 1a and 3a, 2a and 3a, 2b and 3b as P > 0.05. A significant difference was seen among sub-groups 1b and 3b (P<0.05), 1a and 2a, and 1b and 2b (P<0.01). CONCLUSION: Adper Single Bond 2 without diode-laser irradiation before photopolymerization showed the highest shear bond strength, followed by Adper Single Bond 2 irradiated with diode laser before photopolymerization, with the maximum adaptation of dental adhesive to dentin compared to other adhesives used either with or without diode-laser irradiation.

2.
Biomimetics (Basel) ; 9(4)2024 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-38667205

RESUMO

Solvent evaporation within an adhesive layer is a crucial step during a bonding process. The aim of this current research was to test whether the use of different air temperatures (20 °C, 40 °C, and 60 °C) for solvent evaporation improves the performance of four adhesive systems to dentin. Sixty non-carious human molar teeth were randomly prepared for micro-tensile bond strength (µTBS) tests. Four different adhesive systems, Prime&Bond Universal (PBU), OptiBond Universal (OBU), OptiBond FL (OBFL), and Clearfil SE (CSE), were applied following the manufacturer's instructions. Three groups based on the air-drying temperature were used: solvent evaporation was performed with either of warm (40 °C), (60 °C), and cold air as control group (20 °C) for 10 s at a distance of 5 cm. In all bonded surfaces, three resin composite (Reflectys, Itena Clinical, Paris, France) layers of 2 mm thickness were built up. The resin-dentin samples were kept in distilled water at 37 °C for 24 h and 6 months, respectively, before µTBS testing. Failure analysis, scanning electron microscopy of resin-dentin bonded interface, and solvent evaporation rate were tested as secondary variables. All analyses were conducted using a significance level of α = 0.05. Bond strength (BS) values were similar among all the adhesive systems used (p > 0.05). Also, the aging factor did not affect the BS (p > 0.05). Only the factor of temperature used for solvent evaporation resulted in a statistically significant effect (p < 0.05), with the temperature of 60 °C being the highest value (p < 0.05). A failure mode evaluation revealed mostly adhesive or mixed modes of failures in all the different temperatures of air used for the solvent evaporation of each adhesive system. The thickness of the adhesive layer and the creation of resin tags varied amongst the temperatures evaluated. For all adhesive systems tested, the use of 40 °C or 60 °C air for solvent evaporation led to an increased mass loss. Warmer temperatures for solvent evaporation contributed positively to bonding performance, enhancing both the quality of the adhesive layer and its interaction with the dentin tissue. Optimizing solvent evaporation with warmer air temperatures (40 °C and 60 °C) significantly improved µTBS, offering a practical means to enhance the quality and longevity of adhesive restorations in esthetic dentistry.

3.
J Int Soc Prev Community Dent ; 14(1): 43-51, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38559644

RESUMO

Aim: Long-term clinical success on indirect restorations is largely determined by bonding efficiency of the luting agent, with adhesion to dentin being the main challenge. Therefore, aim of this study was to assess the microtensile bond strength when using flowable resin composite, preheated resin composite and dual self-adhesive resin cement as dentin luting agents. Materials and Methods: Occlusal thirds of molar teeth were cut and randomly divided into 3 groups to be cemented: RelyX™U200, Filtek™ Z250 XT- preheated to 70° and Filtek Flow™ Z350XT. They were then thermocycled 5000 times between 5+/-2°C and 55+/-2°C. Subsequently, 10 microbars per group were prepared. The 30 samples were placed in saline solution for 24 hours at room temperature prior to microtensile test. This was performed with a digital universal testing machine at a crosshead speed of 0.5 mm/min. The bond strength values obtained were analyzed in Megapascals (MPa). Measures of central tendency such mean and measures of dispersion such standard deviation were used. In addition, the Kruskall Wallis non-parametric test with Bonferroni post hoc test was applied, considering a significance value of 5% (P < 0.05), with type I error. Results: The dentin microtensile bond strengths of preheated resin composite, flowable resin composite and dual self-adhesive cement were 6.08 ± 0.66 Mpa, 5.25 ± 2.60Mpa and 2.82 ± 1.26Mpa, respectively. In addition, the preheated resin composite exhibited significantly higher microtensile bond strength compared to the dual self-adhesive cement (P < 0.001). While the flowable resin composite showed no significant difference with the dual self-adhesive cement (P = 0.054) and the preheated resin composite (P = 0.329). Conclusions: The microtensile bond strength in dentin was significantly higher when using a preheated resin composite at 70°C as a luting agent compared to dual self-adhesive cement. However, the preheated resin composite showed similar microtensile bond strength compared to the flowable resin composite.

4.
Dent Mater J ; 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38644215

RESUMO

This study aimed to evaluate the effects of different resin-coating technique strategies and dual-cure resin luting materials on proximal marginal adaptation and the microtensile bond strengths (µTBSs) of CAD/CAM hybrid ceramic inlays. Extracted human molars were classified into four groups, depending on the coating technique: No coating (None), single coating (1-coating), double coating (2-coating), and flowable resin-coating (Combination). The inlays were bonded with one of the three materials: Panavia V5 (V5), Rely X Ultimate (RXU), and Calibra Ceram (CC). The differences with regard to adaptation were not significant. In the case of µTBS data for V5, no significant differences were observed, whereas for RXU, µTBS values for Combination statistically exceeded those for None and 1-coating. For CC, µTBS values for Combination statistically exceeded those for None, 1-coating, and 2-coating. The coating techniques did not influence the adaptation but influenced the bond strength, and Combination performed the best.

5.
J Prosthodont Res ; 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38644230

RESUMO

PURPOSE: The purpose of this study is to compare the shear bond strength of ultraviolet (UV)-polymerized resin to 3D-printed denture materials, both with and without post-polymerization. Moreover, the effects of surface treatment and thermocycling on shear bond strength after post-polymerization were investigated. METHODS: Cylindrical 3D-printed denture bases and teeth specimens were prepared. The specimens are subjected to two tests. For Test 1, the specimens were bonded without any surface treatment or thermal stress for comparison with and without post-polymerization. In Test 2, specimens underwent five surface treatments: untreated (CON), ethyl acetate (EA), airborne particle abrasion (APA) with 50 µm (50-APA) and 110 µm alumina (110-APA), and tribochemical silica coating (TSC). A UV-polymerized resin was used for bonding. Half of the Test 2 specimens were thermocycled for 10,000 cycles. Shear bond strength was measured and analyzed using Kruskal-Wallis and Steel-Dwass tests (n = 8). RESULTS: In Test 1, post-polymerization significantly reduced shear bond strength of both 3D-printed denture materials (P < 0.05). No notable difference was observed between the denture teeth and the bases (P > 0.05). In Test 2, before thermocycling, the CON and EA groups exhibited low bond strengths, while the 50-APA, 110-APA, and TSC groups exhibited higher bond strengths. Thermocycling did not reduce bond strength in the latter groups, but significantly reduced bond strength in the EA group (P < 0.001). CONCLUSIONS: Post-polymerization can significantly reduce the shear bond strength of 3D-printed denture materials. Surface treatments, particularly APA and TSC, maintained bond strength even after thermocycling.

6.
Microsc Res Tech ; 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38646819

RESUMO

Evaluation of the impact of the latest root canal disinfectant, that is carbon quantum dots (CQDs), synchronized microbubble-photodynamic activation (SYMPA), and Nd: YAG laser along with ethylenediaminetetraacetic acid (EDTA) as a final irrigant on the Marten hardness (MH), smear layer (SL) removal, and extrusion bond strength (EBS) of zirconia post to the canal dentin. Eighty intact single-rooted premolars were obtained and disinfected using 0.5% chloramine-T solution. Root canal preparation was performed using ProTaper files followed by obturation. The post space was prepared for prefabricated zirconia post and all the teeth were randomly divided into four groups based on the disinfection used (n = 20 each) Group 1: 5.25% NaOCl + 17% EDTA (Control), Group 2: Nd: YAG laser + 17% EDTA, Group 3: SYMPA + 17% EDTA, and Group 4: CQDs + 17% EDTA. MH, SL removal, and EBS of zirconia post-bonded to root dentin were performed using a microhardness tester, scanning electron microscope (SEM), and universal testing machine, respectively. Both intragroup and intergroup comparisons were performed using one-way analysis of variance (ANOVA) and posthoc-Tukey test for significant difference (p < .05). Group 2 samples (Nd: YAG laser + 17% EDTA) (0.24 ± 0.06 GPa) exhibited highest values of MH. Samples in group 3 (SYMPA + 17% EDTA) treated teeth unveiled the lowest MH scores (0.13 ± 0.02 GPa). Moreover, the coronal third of Group 3 specimens (SYMPA and 17% EDTA) (1.54 ± 0.31) eliminated SL from the canal with the greatest efficacy as well as presented the highest EBS (10.13 ± 0.69 MPa). However, the apical third of Group 1 samples (5.25% NaOCl + 17% EDTA) (2.95 ± 0.33) exhibited the least efficient elimination of SL from the radicular dentin as well as the lowest bond strength (5.11 ± 0.19 MPa) of zirconia post to the dentin. The SYMPA technique with 17% EDTA proved highly effective in removing the SL from canal dentin and enhancing the EBS of zirconia posts. The least preferable method for SL removal and MH improvement was found to be 5.25% NaOCl + 17% EDTA. CQDs and Nd: YAG laser demonstrated satisfactory smear layer removal properties from the canal, along with achieving appropriate bond strength of zirconia posts. RESEARCH HIGHLIGHTS: Nd: YAG laser and 17% EDTA as canal disinfectant exhibited the highest values of MH. Specimens irrigated with SYMPA and 17% EDTA eliminated SL from the canal with the greatest efficacy. The coronal third of Group 3 (SYMPA + 17% EDTA) samples unveiled the highest zirconia post-bond integrity score to the canal dentin. Cohesive failure was a dominant failure type among different experimental groups.

7.
Int J Clin Pediatr Dent ; 17(1): 102-108, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38559855

RESUMO

Objective: The present review was conducted to test whether the addition of titanium dioxide (TiO2) nanoparticles (NPs) within orthodontic bracket adhesives would alter their properties and assess their antimicrobial activity against cariogenic microorganisms in addition to noteworthy mechanical properties. Materials and methods: Using predetermined inclusion criteria, an electronic search was conducted using Dissertations and Thesis Global, the Web of Science, Cochrane, Scopus, and Medline/PubMed. Specific terms were utilized while searching the database. Results: Only seven of the 10 included studies assessed shear bond strength (SBS). The mean SBS among the control group varied from 9.43 ± 3.03 MPa to 34.4 ± 6.7 MPa in the included studies, while in the experimental group, it varied from 6.33 ± 1.51 MPa to 25.05 ± 0.5 MPa. Antibacterial activity was assessed in five of the 10 included studies using TiO2 NPs, which could easily diffuse through bacterial media to form the growth inhibition zone. Conclusion: Antibacterial NPs added to orthodontic adhesives at a concentration of 1-5 wt% inhibit bacterial growth and have no effect on bond strength. How to cite this article: D Tivanani MVD, Mulakala V, Keerthi VS. Antibacterial Properties and Shear Bond Strength of Titanium Dioxide Nanoparticles Incorporated into an Orthodontic Adhesive: A Systematic Review. Int J Clin Pediatr Dent 2024;17(1):102-108.

8.
Odontology ; 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38568323

RESUMO

The aim of this study is to investigate the repair bond strength of composite resin following three different surface treatments (bur-grinding, silanization, and Er,Cr:YSGG laser irradiation) using various universal adhesives. A total of 160 resin composite specimens, produced in cylindrical form (6 × 2 mm) with a nanohybrid composite resin within metal molds, were subjected to 5000 cycles of aging in a thermocycler. The aged samples were categorized into four groups based on surface treatments: control, bur, silane, and Er,Cr:YSGG laser. Following surface treatments, the specimens underwent repair using the same resin composite and four different adhesive systems: Tokuyama Universal Bond (TUB), Prime Bond Universal (PBU), Gluma Bond Universal (GBU), and Clearfil SE Bond (CSB). Subsequently, the specimens were subjected to shear forces, and statistical analysis was performed using two-way ANOVA and Tukey tests (p < 0.05). The failure modes were examined using a stereomicroscope, and the surface topography of the roughened resin composite was assessed through scanning electron microscopy (SEM). Results indicated that silane + GBU exhibited the highest shear bond strength (SBS) (15.61 MPa) while control + TUB showed the lowest SBS (7.63 MPa). Silane demonstrated significantly higher SBS values (p ≤ 0.05), with no significant difference observed between bur and laser methods (p = 0.998). It is recommended to include an additional silanization step before applying universal adhesive, as it effectively enhances the bond strength of the repaired composite.

9.
Turk J Orthod ; 37(1): 30-35, 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38556950

RESUMO

Objective: This in vitro study aimed to evaluate the effectiveness of pretreatment with a self-etching primer for bonding aligner attachments to lithium disilicate (LD) and monolithic zirconia (MZ) ceramics. Methods: Forty ceramics, including LD (n=20) and MZ (n=20), were divided into four study groups according to the surface pretreatments: LD specimens pretreated with universal primer (Monobond Plus, MP) after hydrofluoric acid etching (Group 1); MZ ceramics pretreated with MP after sandblasting (Group 2); LD ceramics pretreated with self-etching ceramic primer (Monobond etch & prime, MEP) (Group 3); and MZ ceramics pretreated with MEP after sandblasting (Group 4). The aligner composite (GC Aligner Connect) and universal adhesive (GPremio Bond) were used to prepare the resin attachments. The bond strength was evaluated by micro-shear bond strength (SBS) testing (0.1 mm/min) after thermocycling, and the remnant adhesive was scored according to the resin attachment remnant index (RARI). The SBS data were analyzed using ANOVA and Tukey tests, and the RARI scores were analyzed using the chi-square test. Results: Group 1 had the lowest SBS, and group 2 had the highest SBS. There were significant differences between the groups in terms of bond strength (p<0.05). The RARI scores showed no significant differences, regardless of the pretreatment and ceramic type. Conclusion: The use of a self-etching primer increased the bond strength of resin attachments on LD ceramics. For zirconia ceramics, both ceramic primers are recommended for aligner attachment bonding.

10.
Heliyon ; 10(7): e28324, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38571654

RESUMO

Background: Sealing dental pits and fissures with resin-based sealants effectively prevents occlusal dental caries. The effectiveness of resin-based pit and fissure sealants relies on maintaining a strong bond between the sealant and the enamel. Objective: This in-vitro study compared the micro-tensile bond strength (µTBS) of a conventional resin-based sealant (Clinpro™) and a hydrophilic resin-based sealant (Embrace™ WetBond™) when applied to intact, aprismatic human enamel. Methods: Forty extracted permanent premolar and molar teeth were divided into two groups and paired by tightly approximating two buccal surfaces to create an artificial enamel groove (fissure). Fissure sealants (Clinpro™ and Embrace™ WetBond™) were applied to the artificial enamel 'grooves' in each group. The specimens were then cut into beams with a cross-sectional area of 1 mm2 and tested for the micro-tensile bond strength (µTBS). Fractured surfaces of samples were examined under a conventional microscope to identify the failure modes. Two specimens from each group were prepared and observed under a scanning electron microscope (SEM). Mann-Whitney U and Fischer-Freeman-Holton exact tests were used to test the statistical differences between the fissure sealants. Results: The µTBS mean ± SD for Clinpro™ was 16.43 ± 7.08, and 10.57 ± 6.64 for Embrace™ WetBond™. There was a statistically significant difference in µTBS between Embrace™ WetBond™ and Clinpro™ (p < 0.001). There was no association between fissure sealant and failure modes (p = 0.922). Conclusion: Clinpro™ showed higher µTBS to enamel than Embrace™ WetBond™. Further studies are needed to conclude the clinical effectiveness of these sealants.

11.
Iran Endod J ; 19(2): 112-119, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38577005

RESUMO

Introduction: The final step of irrigation has been considered to of increase the bonding strength of filling material to dentin. This study investigated the impact of three final-step irrigation methods on the endodontic sealer bond strength to dentin by using a micro push-out test. Materials and Methods: Palatal roots of human maxillary molars were cleaned and shaped and randomly divided in six groups (n=15) according to the final-step irrigation method and the type of root canal sealer used. The solutions used for the final-step irrigation were 17% ethylenediaminetetraacetic acid and 2.5% sodium hypochlorite, which underwent three methods: 1) syringe-needle irrigation/conventional, 2) passive ultrasonic irrigation, and 3) XP-endo Finisher agitation. The root canal sealers used were: EndoSequence BC Sealer, and AH-Plus sealer. Roots were obturated with the single cone technique and then, cross-sectioned in 2-mm-thick slices (3 slices from each root). Push-out test was performed on the sliced specimens (cervical, middle, and apical thirds) with a universal testing machine. Bond strength values were recorded in megapascal (MPa). Subsequently, each specimen was longitudinally split to verify the type of failure. Data analysis was performed using Johnson transformation, three-way analysis of variance, Tukey's post-hoc tests, and the partial Eta squared test. Results: There were significant differences in bond strength between the sealers [AH: 4.46±2.24 and BC: 3.47±2.19 MPa (P<0.001)]; between final-step irrigation methods [passive ultrasonic irrigation: 4.52±2.25, XP-endo Finisher: 3.93±3.93 and syringe-needle irrigation/conventional: 3.37±2.51 MPa (P<0.001)], and between the root canal thirds represented by the sliced specimens [cervical: 5.45±2.39, middle: 4.14±1.99 and apical: 2.30±1.30 MPa (P<0.001)]. The interaction between the variables had no significance (P>0.05). Conclusion: Agitation of the final irrigating solution may improve the bonding of the sealer to canal walls. AH-Plus sealer had the highest bond strength. The bond strength reduced significantly towards the apical third.

12.
Microsc Res Tech ; 2024 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-38581370

RESUMO

To incorporate different concentrations of Al2O9Zr3 (1%, 5%, and 10%) nanoparticles (NP) into the ER adhesive and subsequently assess the impact of this addition on the degree of conversion, µTBS, and antimicrobial efficacy. The current research involved a wide-ranging examination that merged various investigative techniques, including the application of scanning electron microscopy (SEM) for surface characterization of NP coupled with energy-dispersive x-ray spectroscopy (EDX), Fourier-transform infrared (FTIR) spectroscopy, µTBS testing, and microbial analysis. Teeth were divided into four groups based on the application of modified and unmodified three-step ER adhesive primer. Group 1 (0% Al2O9Zr3 NPs) Control, Group 2 (1% Al2O9Zr3 NPs), Group 3 (5% Al2O9Zr3 NPs), and Group 4 (10% Al2O9Zr3 NPs). EDX analysis of Al2O9Zr3 NPs was performed showing elemental distribution in synthesized NPs. Zirconium (Zr), Aluminum (Al), and Oxides (O2). After primer application, an assessment of the survival rate of Streptococcus mutans was completed. The FTIR spectra were analyzed to observe the characteristic peaks indicating the conversion of double bonds, both before and after the curing process, for the adhesive Etch and rinse containing 1,5,10 wt% Al2O9Zr3 NPs. µTBS and failure mode assessment were performed using a Universal Testing Machine (UTM) and stereomicroscope respectively. The µTBS and S.mutans survival rates comparison among different groups was performed using one-way ANOVA and Tukey post hoc (p = .05). Group 4 (10 wt% Al2O9Zr3 NPs + ER adhesive) specimens exhibited the minimum survival of S.mutans (0.11 ± 0.02 CFU/mL). Nonetheless, Group 1 (0 wt% Al2O9Zr3 NPs + ER adhesive) displayed the maximum surviving S.mutans (0.52 ± 0.08 CFU/mL). Moreover, Group 2 (1 wt% Al2O9Zr3 NPs + ER adhesive) (21.22 ± 0.73 MPa) samples displayed highest µTBS. However, the bond strength was weakest in Group 1 (0 wt% Al2O9Zr3 NPs + ER adhesive) (14.13 ± 0.32 MPa) study samples. The etch-and-rinse adhesive exhibited enhanced antibacterial activity and micro-tensile bond strength (µTBS) when 1% Al2O9Zr3 NPs was incorporated, as opposed to the control group. Nevertheless, the incorporation of Al2O9Zr3 NPs led to a decrease in DC. RESEARCH HIGHLIGHTS: 10 wt% Al2O9Zr3 NPs + ER adhesive specimens exhibited the minimum survival of S.mutans. 1 wt% Al2O9Zr3 NPs + ER adhesive samples displayed the most strong composite/CAD bond. The highest DC was observed in Group 1: 0 wt% Al2O9Zr3 NPs + ER adhesive.

13.
Photodiagnosis Photodyn Ther ; : 104076, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38582390

RESUMO

AIMS: Impact of different post-space disinfectants (Saline, Sodium hypochlorite (NaOCl) followed by ethylene-diamine-tetra-acetic acid (EDTA) and curcumin activated by microbubble emulsion (MBE) on the Vickers hardness (VH) of root canal dentin and extrusion bond strength (EBS) of Glass fiber post (GFP) and PEEK post. METHODS: Ninety maxillary central incisors having fully formed roots were included. After the specimen's disinfection, root canal treatment was completed. Post space was prepared by removing gutta-percha using gates glidden drills. Teeth were then arbitrarily allocated into three groups based on the methods of disinfection regime used. Group 1: Saline, Group 2: NaOCl+ EDTA and Group 3: Curcumin activated by MBE (n=30). Analysis of VH of radicular dentin was performed using a micro-Vickers tester on ten samples from each group. After post-space disinfection, twenty specimens from each group were further divided into two subgroups (n=10) In group-1A 2A, and 3A, GFP was used. Whereas, prefabricated PEEK posts were used in 1B, 2B, and 3B subgroups. The PBS and failure modes were performed using a universal testing machine and stereomicroscope respectively. Data was analyzed using ANOVA and Tukey post hoc test to identify significant variations among groups concerning the MH and EBS of the different posts used (p=0.05). RESULTS: Group 2 (5.25% NaOCl + 17% EDTA) (0.15 ± 0.02 GPa) treated specimens presented lowest scores of VH. However, Group 1 (Saline) irrigated canals displayed the highest scores of surface hardness (0.25± 0.07 GPa). Additionally, a cervical third of 3A (CP activated by MBE + GFP) (11.22±0.79 MPa) presented the highest scores of bond integrity. Whereas Group 1B (Saline + PEEK post) treated specimens presented the lowest scores of PBS (4.15±0.15 MPa). CONCLUSION: Curcumin activated by microbubble emulsion for disinfection of canal dentin demonstrated favorable VH. Similarly, glass fiber post-cemented in radicular walls disinfected with curcumin activated with MBE showed promising post-bond integrity to the canal dentin.

14.
Microsc Res Tech ; 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38661299

RESUMO

This research was aimed to evaluate push-out bond strength and apical-microleakage after application of three different calcium silicate-based cements with irrigation solutions on simulated immature teeth. 40 maxillary permanent canine teeth were used for push-out bond strength test, and 120 maxillary permanent incisors were used for microleakage evaluation. 120 root slices were divided into four main groups (EDTA, Chitosan, Phytic acid, and Saline) and immersed these solutiouns according to irrigation procedures. Each irrigation group was divided into 3 subgroups (Biodentine, MTA Repair HP, and NeoPUTTY). The prepared teeth were divided into four groups according to irrigation procedure for microleakage test. EDTA irrigation with Biodentine group showed highest push-out bond strength value and saline group with Neoputty showed the lowest push-out bond strength value. The highest microleakage value was seen in saline group with MTA Repair HP, while the lowest microleakage value was observed chitosan with Biodentine group. Chitosan and phytic acid solutions can be recommended as an alternative irrigation solution to 17% EDTA in single-session apexification treatment, since they are non-toxic, naturally occurring materials, effectively remove the smear layer, and have a positive effect on bond strength and apical leakage. RESEARCH HIGHLIGHTS: One of the factors affecting the long-term success of root canal treatment is a hermetic seal. Non-hermetic or inadequate filling triggers a chronic inflammatory reaction in periapical tissues, causing fluids to enter the spaces and negatively affecting the success of the treatment. Therefore, this study will help clinicians choose the right biomaterial and irrigation solution that will affect the success of root canal treatment.

15.
Photodiagnosis Photodyn Ther ; : 104088, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38631620

RESUMO

AIM: Assessment of contemporary canal medicaments (Triple antibiotic paste (TAP), Bio-C Temp, and Nano silver gel activated by visible blue light on the dentin microhardness (MH) and push-out bond strength (PBS) of AH plus endodontic sealer METHOD: : Sixty extracted premolars were obtained and decontaminated. Canal cleaning and shaping were performed. The samples were randomly allocated into four groups based on the intracanal medicaments. Group 1= CH paste, Group 2= TAP, Group 3= Bio-C Temp, and Group 4= Nano-silver gel activated by visible blue light. MH assessment was performed using a Vickers Microhardness tester. Forty specimens, ten from each group underwent root canal obturation. PBS and failure mode evaluation were performed. ANOVA and Post Hoc Tukey test were utilized to conduct intra and inter-group comparisons RESULTS: : The maximum outcome of surface hardness was presented by Group-3 (Bio-C Temp®) specimens. However, minimum scores of MH were displayed by Group 1 (CH) treated teeth. The highest outcomes of EBS were exhibited by the cervical third of Group 3 (Bio-C Temp®) samples. The apical section of Group 4 Teeth with Nano Silver gel activated by visible blue light revealed the lowest scores of bond integrity CONCLUSION: : Bio-C Temp and TAP proved to be better intracanal medicament than other tested groups in terms of the push-out bond strength of the sealer. TAP displayed lower microhardness as compared to the Bio-C Temp.

16.
Cureus ; 16(3): e56320, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38629015

RESUMO

Background The challenges associated with incorporating antimicrobial agents, such as the potential diminishment of the cement's physical properties, highlight the need for comprehensive evaluations. Balancing antimicrobial efficacy with the maintenance of structural integrity is a crucial aspect of material development. The acknowledgment of cytotoxic properties associated with tricalcium aluminate, a major constituent in conventional mineral trioxide aggregate (MTA), is critical in terms of long-term evaluation of treatment procedures. The primary focus of the push-out test is to evaluate the resistance of the tested material to dislodgement. Greater push-out strength implies stronger adhesion between the tested material and the tooth surface. Aim This study aims to evaluate the push-out bond strength of two antibacterial-enhanced MTAs with conventional MTA and Biodentine. Material and methods A total of five materials were tested: a) modified MTA, b) doxycycline-enhanced MTA, c) metronidazole-enhanced MTA, d) conventional MTA, and e) Biodentine. All the materials were mixed based on a predetermined powder:liquid ratio and then carried using a plastic instrument to the desired experimental design. Single-rooted permanent teeth, preferably incisors, were used in the present study. Teeth were embedded vertically in a rubber mold, and sectioning of the tooth was performed. A single operator instrumented the canal space in each slice using Gates-Glidden burs, and the mixed cements were placed in the respective groups and stored for 72 hours. A push-out test was carried out using a universal testing machine. Following the bond failure, the slices were examined under a stereomicroscope to determine the nature of the bond failure. The collected data was subjected to a one-way analysis of variance test, post hoc test, and chi-square test for statistical analysis. Results The mean push-out bond strength was found to be the highest for Biodentine (43.25 ± 0.62 megapascals (MPa)), followed by doxycycline- and metronidazole-enhanced MTAs (39.54 ± 0.65 MPa and 39.29 ± 0.16 MPa, respectively), modified MTA formulation (37.75 ± 0.73 MPa), and the lowest for conventional MTA (25.93 ± 0.7 MPa). Conventional MTA samples had an adhesive failure (89.4%), while Biodentine samples had a cohesive failure (80.3%). Mixed failures were noticed with the samples containing modified MTA formulation (71.3%), doxycycline-enhanced MTA (76.6%), and metronidazole-enhanced MTA (78.0%). Conclusion Despite not surpassing Biodentine in bond strength, antibacterial-enhanced MTAs are considered potential alternatives to conventional MTA in day-to-day clinical practice.

17.
Artigo em Inglês | MEDLINE | ID: mdl-38588575

RESUMO

Objective: Assessment of different remineralizing pretreatment casein phosphopeptide-amorphous calcium phosphate (CPP-ACP), proanthocyanidin (PA), carbon dioxide laser (CO2), eggshell solution (ES) on the shear bond strength (SBS) of resin composite bonded to remineralized carious-affected dentin (CAD). Materials and methods: Eighty human molars were collected with occlusal caries that extended about halfway into the dentin. Using a water-cooled, low-speed cutting saw, a flat, mid-coronal dentin surface was exposed. CAD was differentiated from healthy dentin. Based on the remineralizing agent used on the CAD surface, the teeth were arbitrarily allocated into five groups (n = 10). Group 1: no remineralizing agent, Group 2: CPP-ACP, Group 3: 6.5% PA solution, Group 4: CO2 laser, and Group 5: ES solution. All samples were bonded to composite and light cured and thermocycled. SBS and failure mode analysis were performed using universal testing and stereomicroscope 40 × . Using SPSS, SBS, and failure mode data were analyzed using analysis of variance and Tukey's honesty significant difference (HSD) test Results: Group 3 (6.5% PA solution; 15.59 ± 1.44 MPa) samples established the maximum bond integrity. Nevertheless, Group 1 (No remineralizing agent; 11.19 ± 1.21 MPa) exhibited the minimum outcome of bond strength. Intergroup comparison analysis showed that Group 1 (No remineralizing agent), Group 2 (CPP-ACP), and Group 4 (CO2 laser) established comparable values of bond strength (p > 0.05). Likewise, Group 3 (6.5% PA solution) and Group 5 (EA solution) also revealed equivalent bond integrity (p > 0.05). Conclusions: PA and ES are considered potential remineralizing agents used for caries-affected dentin surfaces in improving bond integrity to composite resin. However, further studies are advocated to extrapolate the findings of this study.

18.
Artigo em Inglês | MEDLINE | ID: mdl-38591503

RESUMO

OBJECTIVES: In-office and lab milled prostheses are the staple for indirect restorations. It is therefore critical to determine their long-term bonding durability. METHODS: CAD/ CAM blocks of two classes of restorative materials: 1) a nano-ceramic reinforced polymer matrix (NCPM) and, 2) a polymer-infiltrated ceramic network (PICN) were bonded using four different universal adhesives (UA) and silane systems. A lithium disilicate glassceramic (LDS) was used as a reference. The blocks were bisected and bonded with different UA/resin-cement pairs. Bonded blocks were then cut into 1.0x1.0x12.0 mm bar specimens for microtensile bond testing. Half the bars were subjected to bond strength testing immediately and the other half after aging by 50,000 thermal cycles between 5°C and 55°C. ANOVA and post-hoc tests were used to compare mean bond strength among groups. RESULTS: NCPM presented consistently high bond strength regardless of bonding techniques, while the bond strength of PICN and LDS were lower when bonded with UA relative to traditional silanes. The more hydrophilic UA produced higher bond strengths. DISCUSSION: Glass-ceramics exhibited lower bond strength with UA than the conventional etch-rinse-silane techniques. However, UAs preserved bonding interface in the long-term. SIGNIFICANCE: NCPM displayed superior bond strength relative to PICN and LDS regardless of the type of adhesives and bonding techniques.

19.
J Pharm Bioallied Sci ; 16(Suppl 1): S180-S182, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38595347

RESUMO

Background: The aim of this study was to evaluate the effect of separately curing the unfilled resin for increased bond strength of the orthodontic brackets as the literature shows both studies that support and contradict this aspect. Methodology: The sample consisted of 120 specimens randomly grouped into four of 30. The tooth was cleaned of tissue and debris and stored in a distilled water solution until the procedures of bonding. The surface of the enamel was conditioned with pumice, and acrylic blocks were designed for the tooth to be mounted onto them. The buccal surfaces of all the teeth were prepared by etching the enamel with 37% phosphoric acid for a time period of 30 seconds and washed for 20 seconds under running water. Stainless steel brackets (Victory Series™ MBT, 0.022 Slot) were used for all the samples in the study, and the bonding procedure was conducted on the same day for all the groups. The artificial saliva was used for the storage of samples for 24 h after bonding, and shear bond strength testing was conducted using an Instron machine in shear or peel mode at a crosshead speed. Results: The highest mean bond strength calculated was for the conventional technique (17.45 mpa), while it was the lowest for no primer adhesive (11.21 mpa). Group IV had a greater distribution of ARI scores than groups I, II, and III. Conclusion: Group IV achieved the highest bond strength when compared to other groups, with an ARI score of 3. Group III had less bond strength, likely due to incomplete curing of the primer due to insufficient exposure to light. Transbond XT can be used without primer, making bonding, debonding, and cleaning procedures easy and less time-consuming.

20.
J Pharm Bioallied Sci ; 16(Suppl 1): S702-S703, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38595381

RESUMO

Objectives: To assess a bracket-bonding system's shear bond strength cured with dissimilar light-curing units at different time intervals. Materials and Method: Sixty premolar teeth removed for orthodontic purposes were categorized into four types based on the light-curing unit and exposure times used. The specimens in the halogen group were exposed to light for 15 (Group I) and 30 (Group II) sec, respectively. The specimens were exposed to light for 10 (Group III) and 15 sec in the LED group (Group IV). The amount of adhesive still present on the teeth was measured using a stereomicroscope at a magnification of 10 and was then assessed with the help of adhesive remnant index (ARI). Result: The group with the highest mean SBS was in Group II followed by Group I, Group III, and the group with the lowest mean SBS. The ARI was unaffected by the light-curing technique, with score 2 predominating. Conclusion: In all groups, polymerization using halogen and LED led to SBS values that were clinically suitable for orthodontic procedures.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...